September 16, 2009
This unit is being sold because facility has upgraded their equipment.


No. 10505: CONTINENTAL TM-40 Rad Room

You are bidding on a Continental TM-40 Rad Room.
stats Advertisement
DOTmed text ad

Training and education based on your needs

Stay up to date with the latest training to fix, troubleshoot, and maintain your critical care devices. GE HealthCare offers multiple training formats to empower teams and expand knowledge, saving you time and money

stats

-There is a 4 way floating top table that elevates manufactured by Continental July 1996.
-The room comes with original tube from 1996 manufactured by Varian.
-The Continental generator was manufactured in 1996.
-The Generator is rated at 40 KW 125 KVP and 300 MA.
-The Control is a Continental Tm-40 manufactured in 1996.
-The tube stand is a floor to wall system manufactured in 1996.
-Linear X-ray Collimator was manufactured in 1996.
-There is a upright bucky that goes all the way to the floor.
-The Bucky trays were manufactured in 1996.
-This room comes with a set of manuals
-The table weight limit is 300 lbs.
-This room is in good working condition.
-The clinic is a small single floor clinic that doesn't do many x-rays.
-The room hasn't had any problems and everything has worked well.


No. 9876: SIEMENS COROSKOP H.I.P Cath Lab

You are bidding on a 2000 SIEMENS COROSKOP H.I.P CATH LAB.
This special procedure room comes with the following:
-Polydoros IS-C Generator
-Koordinat M Table
-Coroskop H.I.P C-Arm
-Videomed S Camera System
-23/33/40 Image Intensifier
-Hicor
-ACOM-M
This room was fully inspected by a qualified engineer on 9/12009.

Report details:
1. - The system Boot up completely including the HICOR
2. - The X-Ray tube (Megalix 125/30/82 -120 GW) was replaced in 2004
3. - There are monitors missing from the MTS (ceiling mounted monitors hanger) and the monitor in the control area.
3. - We did flouro and acquisition.

This room is coming out of a prestigious health care group and is being sold because facility is updating their equipment.


No. 9874: SIEMENS COROSKOP HS Cath Lab

You are bidding on a 1994 SIEMENS COROSKOP HS CATH LAB.
This special procedure room comes with the following:
-Polydoros IS-C Generator
-Koordinat U Table
-Coroskop HS-ASC C-Arm
-Videomed H Camera System
-23/33/40 Image Intensifier
-Hicor
-Cathcor
-ACOM-M
This room was fully inspected by a qualified engineer on 9/12009.

Report details:
1. - Could not power up due to power availability.
2. - The X-Ray tube (Megalix 125/30/82 -120 GW) was replaced in 2006
3. - The Cathcor is missing the computer.

This room is coming out of a prestigious health care group.