SEARCH
Endroit courant :
>
> SIEMENS Siremobil 2000 5c

Flag this model as duplicate or for review

Want to Buy A SIEMENS Siremobil 2000 5c C-Arm?

Post an RFP in minutes

Post a free Request for Proposal and get quotes on equipment you are looking to buy from DOTmed's Gold Service Dealers!

Find All Used, New, and Refurbished SIEMENS Siremobil 2000 5c C-Arm For Sale Listings on DOTmed

SIEMENS Siremobil 2000 5c C-Arm

Description

Caractéristiques

Model Rating

Not Rated
Rate This Model Now
Information Provided By:
The mobile C-arm MULTIMOBIL 5C provides the optimum solution of today's clinical requirements. It is ideally suited for entry level surgery in many application fields such as orthopedics, trauma surgery, general surgery.

Special Features
◾Standby mode eliminates accidental radiation release during transportation
◾Image rotation for visualization of images irrespective of position of organ
◾Thermal protection

Mobile C-arm Image Intensifier System with High Frequency Technology
Can be used for therapeutic procedures in
◾OR
◾Radiological departments
◾Emergency rooms

The automatic dose regulation constantly adapts the X-ray radiation to the thickness and density of the irradiated body part.

Extension with digital image memory provides storage for four fluoroscopy images. This simplifies the diagnosis while reducing in radiation dose and total fluoroscopy time.

High resolution compact image intensifier system with
◾CCD camera
◾Excellent spatial resolution with 0.5 and 1.5 focal spots

Single-tank high-frequency X-ray generator
◾Automatic dose regulation

Digital control unit with
◾Four image storages
◾Last Image Hold (LIH)

All components are ideally matched for delivering consistent image quality.

C-arm
Orbital movement 125° (-35° to +90°)
Angulation ±190°
Horizontal movement 20 cm (7.9")
Swivel range ±12.5°
Vertical Travel 40 cm (15.7")
Source - I.I. distance 86 cm (33.8")
Immersion depth 63.5 cm (25")
Lateral movement steering handle

X-ray generator


Type 2.5 kW/190-240 V; 1.6 kW/110 V
Radiographic parameters
kV range 40 kV to 100 kV in 20 steps
mAs 0.32 mAs to 200 mAs in 29 steps
mA 13 mA to 63 mA/190-240 V; 10 mA to 40 mA/110V
Time 20 ms to 5 s/190-240 V; 20 ms to 8 s/110 V
Fluoroscopic parameters
Fluoroscopy voltage 40 kV to 110 kV
mA range anti-isowatt 0.5 mA to 5 mA
contrast 0.5 mA to 7 mA
Fluoroscopy ADR (Automatic Dose Regulation) and manual mode

X-ray tube unit


Type stationary anode dual focus
Focal spot sizes, minimal value 0.5/1.5 mm
Selection automatic selection of focal spot for fluoroscopy and radiography
Thermal protection auto cut-off of fluoroscopy and radiography in case of tube head
temperature exceeding 60 °C
Collimator system motorized iris collimator for concentric collimation

X-ray image intensifier


Nominal diameter 23 cm (9")
Field size dual field 23 cm (9")/16 cm (6") selectable from the control panel
circular grid placed at the input of the I.I.
Grid Pb 8:1; 40 lp/cm, f0 90

Cassette holder


Format auto centering 10" x 12" format

TV system


Type CCD camera with high sensitivity and resolution
TV standard CCIR 625 lines at 50 Hz
Matrix size of CCD camera 752 (H) x 582 (V) for 50 Hz effective pixel
Image rotation endless clockwise and anti clockwise
Image reversal left/right and top/bottom
Displays 2 x 15" black and white TFT displays for live image and
Last Image Hold (LIH)
high brightness, high resolution with independent
brightness and contrast control
Digital image storage capacity standard four frame image memory in addition to LIH

Power Supply


Power requirement maximum 3.5 kVA
Main voltage single phase 110V AC ± 10%, 50 Hz and 60 Hz
at line resistance of 0.36 ohms
single phase 190V - 240V AC ± 10%, 50 Hz and 60 Hz
at line resistance of 1.5 ohms

Accessories


Cloth cover and clips for C-arm, X-ray tube and I.I.
Cassette holder standard
Interface to external recording device optional
Thermal printer optional

Environment conditions (operating)

Temperature range +10ºC to +40ºC
Relative humidity 30% to 75%
Barometric pressure 700hPa to 1060hPa

 

Reviews

Forums

Share your opinion or experience with this equipment - Review this model

Amber Diagnostics -Industry's First CMOS Digital Detector C-Arm Retrofit

Retrofit your C-arm Today! Full Field Radiographic Capability, Higher Detailed Resolution, Dose Reduction, Increased Field of View, Reduced Noise With Increased Contrast & More. Call 1-407-438-7847 (USA Toll Free: 1-888-561-7900) Visit www.AmberUSA.com DOTmed 100

Publicité
Développez la notoriété de votre marque
Enchères + Ventes Privées
Obtenir le meilleur prix
Acheter des équipement / pièces
Trouver le meilleur prix
Infos du jour
Lire Les dernières nouvelles
Annuaire
Consulter tous les utilisateurs DOTmed
Éthique concernant DOTmed
Voir notre programme d'éthique
L'or partie le programme de fournisseur
Recevoir des demandes PH
Programme de marchand de service d'or
Recevoir des demandes
Fournisseurs de soins de santé
Voir tous les outils des HCP (abréviation pour les professionnels de la santé)
Les travaux/Formation
Trouver / combler un poste
Parts Hunter +EasyPay
Obtenir des devis de pièces
Certification Récentes
Voir les utilisateurs récemment certifiés
Evaluation Récentes
Voir les utilisateurs récemment certifiés
Central de location
Louer de l’équipement à moindre prix
Vendre des équipements / pièces
Obtenir le maximum d'argent
Service le forum de techniciens
Trouver de l'aide et des conseils
Simple demande de propositions
Obtenir des devis pour des appareils
Expo Virtuelle
Trouver des services d'appareils
L'Access et l'utilisation de cet emplacement est sujet aux modalités et aux conditions du notre de nos MENTIONS LEGALES & DONNEES PERSONELLES
Propriété de et classe des propriétaires DOTmedà .com, inc. Copyright ©2001-2019 DOTmed.com, Inc.
TOUS DROITS RÉSERVÉS