We provide sales, service, rental, and repair for ultrasound systems, probes, and C-arms. We have the largest inventory in the world. Contact us about our special offers on certified refurbished equipment! Call: 317-759-9210 Email: sales@probomedical.com.
North America's trusted source for ultrasound probe repair and certified refurbished OEM probes. Free evaluations, 1-year warranty, fast turnaround for GE, Philips, Sonosite, Canon, Toshiba, and more. Call (224) 265-7640 / Sales@Lenard.Healthcare
Faulty Phenomenon Malfunction: when turning on the device during the operation process, an error with the diagnostic code DiagCode:200 appears. J49P. 3FXS. 5. No possibility to work, requires... voir plus
Faulty Phenomenon Malfunction: The device does not respond to the power button, the indicators on the Power Supply block do not light up. Faulty radio components in PFC (input section) have been... voir plus
Faulty Phenomenon A malfunction was detected in the Channel Board (part of Acquisition Module A. X Hardware). Error 005 has a general nature, it was an error due to an excess current in one of the... voir plus
Faulty Phenomenon Malfunction: error 607 indicates a malfunction in the data base solution: after restarting the PO device, it worked. Troubleshooting and Solutions Malfunction: error 607... voir plus
Faulty Phenomenon Repair 2 Philips Epiq 7G devices malfunction: During the examination in all modes of operation on all sensors, interference appears; the device freezes and works incorrectly. The... voir plus
Faulty Phenomenon Repair of Philips Epiq 5/7 with errors 503, 514, 525, 608 malfunction: when turning on the Epiq 5/7 device, errors 503, 514, 525, 608 (photos uploaded) appear. Troubleshooting and... voir plus
Faulty Phenomenon Repair Acquisition Module for A. X hardware (PN: 453561704245) of the Philips Epiq 5/7 device. Malfunction: During the examination in all modes of operation and on all sensors,... voir plus
Faulty Phenomenon Repair the motherboard of the Philips Epiq 5G device malfunction: the device does not turn on and does not respond to the power button. Troubleshooting and Solutions Repair of... voir plus
Faulty Phenomenon A red "X" appeared next to patient information in the review screen and on stored images. Troubleshooting and Solutions Philips IE33 Red Cross Display Issue - Fixed --- ❓... voir plus
Faulty Phenomenon The system faileFaulty Phenomenon The system failed to start, stopping at "initializing hardware" screen or showing Error 606 during boot-up. Troubleshooting and Solutions ... voir plus
Faulty Phenomenon System displayed "Error 602" during operation. Troubleshooting and Solutions Philips IE33 Error 602 - Memory Issue Resolved --- 💻 Problem Reported System displayed... voir plus
Faulty Phenomenon The Philips IE33 system experienced intermittent crashes showing Error 200, requiring complete power cycling to restore function. Troubleshooting and Solutions Philips IE33... voir plus
Faulty Phenomenon The system repeatedly froze during use, becoming completely unresponsive. Error messages about a "new keyboard" appeared before crashes. Troubleshooting and Solutions Philips... voir plus
Faulty Phenomenon The system displayed a blue screen error (code: 0x000000ED) on startup and could not proceed to normal operation. Troubleshooting and Solutions Philips CX50 Blue Screen Error -... voir plus
Faulty Phenomenon The Philips CX30 system started up normally but frequently crashed during operation, showing "new keyboard detected" errors. Troubleshooting and Solutions Philips CX30 System... voir plus