Over 1650 Total Lots Up For Auction at Two Locations - PA 07/14, NJ Cleansweep 07/16

stats
DOTmed text ad

Probo Medical | We Buy, Repair, and Sell New and Used Ultrasound Equipment

We provide sales, service, rental, and repair for ultrasound systems, probes, and C-arms. We have the largest inventory in the world. Contact us about our special offers on certified refurbished equipment! Call: 317-759-9210 Email: sales@probomedical.com.

stats
stats
DOTmed text ad

North America's Ultimate Probe Repair Lab & Certified Refurbished OEM Probes in Stock

North America's trusted source for ultrasound probe repair and certified refurbished OEM probes. Free evaluations, 1-year warranty, fast turnaround for GE, Philips, Sonosite, Canon, Toshiba, and more. Call (224) 265-7640 / Sales@Lenard.Healthcare

DOTmed Certified stats
MyLab™A70 from Esaote
MyLab™A70 from Esaote
New Product Showcase
spacer
Par page

Annonces

Service For GE HEALTHCARE GE Vivid E9 Image Display Issue GE Vivid E9 Image Display Issue

Faulty Phenomenon When using the 4C probe for abdominal scanning, the VE9 system occasionally displayed a vertical brightness boundary line on the image. The issue appeared intermittently and only... voir plus

June 21  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE GE Vivid E9 Display Color Issue GE Vivid E9 Display Color Issue

Faulty Phenomenon The 17-inch main monitor showed discoloration and streaks, while the workstation display remained normal - indicating a display-specific issue. Troubleshooting and Solutions GE... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE GE Vivid E9 System Boot Failure GE Vivid E9 System Boot Failure

Faulty Phenomenon The GE Vivid E9 ultrasound system failed to start properly. During boot-up, the progress bar showed an error message, then the screen turned black and the system shut down... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE GE Vivid 7 Color Imaging Issue GE Vivid 7 Color Imaging Issue

Faulty Phenomenon GE Vivid 7 ultrasound system showed poor color image quality with high-frequency abdominal probes, while the cardiac probe (M3S) worked normally with clear color images ... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE GE vivid7 cannot be start up GE vivid7 cannot be start up

Faulty Phenomenon The GE Vivid 7 ultrasound system failed to start up. After pressing the On/Standby button, the system showed no response and could not begin normal operation. Troubleshooting... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE GE Voluson730 color doppler image lose GE Voluson730 color doppler image lose

Faulty Phenomenon GE Voluson730 ultrasound system showed partial image loss across all connected probes, affecting imaging quality Troubleshooting and Solutions GE Voluson730 Ultrasound System... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE GE LOGIQ E9: The Operate Keyboard is Out of Control The Operate Keyboard is Out of Control

Faulty Phenomenon The system's operate keyboard remained locked even after pressing the unlock button, preventing normal operation. Troubleshooting and Solutions GE LOGIQ E9 Keyboard Lock... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE GE Voluson E8 No Image Display GE Voluson E8 No Image Display

Faulty Phenomenon The GE Voluson E8 ultrasound system could start up and switch probes normally, but the scanning area showed no image, making examinations impossible. Troubleshooting and... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE GE LOGIQ E9 Frequent Crashes GE LOGIQ E9 Frequent Crashes

Faulty Phenomenon The GE LOGIQ E9 ultrasound system frequently crashes during startup, preventing normal operation. Troubleshooting and Solutions GE LOGIQ E9 Frequent Crashes - Power Supply... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE GE LOGIQ E Portable Ultrasound - Power Issue GE LOGIQ E Portable Ultrasound - Power Issue

Faulty Phenomenon The portable ultrasound unit shuts down automatically during startup, only reaching about halfway through the boot process. Troubleshooting and Solutions GE LOGIQ E Portable... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE GE Vivid E9 Automatic Shutdown Issue GE Vivid E9 Automatic Shutdown Issue

Faulty Phenomenon The Vivid E9 system repeatedly shut down unexpectedly during normal operation. It could be restarted, but the issue recurred after some time. Troubleshooting and Solutions GE... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE GE Voluson E8 System Blue Screen GE Voluson E8 System Blue Screen

Faulty Phenomenon The system repeatedly experienced blue screen errors with "system file missing" messages. While reinstalling the system provided a temporary fix, the problem returned within a... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE GE Vivid E9 Monitor Display Issue GE Vivid E9 Monitor Display Issue

Faulty Phenomenon The main monitor showed a blurry display while the system booted normally. The touchscreen display and all system functions worked properly. Troubleshooting and Solutions GE... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE GE Vivid 7 Overheating & Shutdown Issue GE Vivid 7 Overheating & Shutdown Issue

Faulty Phenomenon GE Vivid 7 system worked normally for about 30 minutes after startup, then suddenly went blank and became completely unresponsive to restart attempts. Troubleshooting and... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE GE Vivid 7 System Crash GE Vivid 7 System Crash

Faulty Phenomenon GE Vivid 7 system experienced repeated crashes over three weeks: - Initially crashed twice within two weeks - Completely failed to start in third week - Displayed error:... voir plus