Over 1650 Total Lots Up For Auction at Two Locations - PA 07/14, NJ Cleansweep 07/16

stats
DOTmed text ad

North America's Ultimate Probe Repair Lab & Certified Refurbished OEM Probes in Stock

North America's trusted source for ultrasound probe repair and certified refurbished OEM probes. Free evaluations, 1-year warranty, fast turnaround for GE, Philips, Sonosite, Canon, Toshiba, and more. Call (224) 265-7640 / Sales@Lenard.Healthcare

DOTmed Certified stats
stats
DOTmed text ad

Probo Medical | We Buy, Repair, and Sell New and Used Ultrasound Equipment

We provide sales, service, rental, and repair for ultrasound systems, probes, and C-arms. We have the largest inventory in the world. Contact us about our special offers on certified refurbished equipment! Call: 317-759-9210 Email: sales@probomedical.com.

stats
MyLab™A70 from Esaote
MyLab™A70 from Esaote
New Product Showcase
spacer
Par page

Annonces

Service For GE Voluson E10 EM6C

GE 3D/4D convex ultrasound probe EM6C showing error Service scope: showing error, motor control problem, replace dome, replace cable,replace plastic cover and connector. test video/pics will be... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE VolusonE6 VolusonE8 RIC5-9-D

GE 3D/4D endocavity ultrasound probe RIC5-9-D replace crystal and replace dome Service scope: showing error, motor control problem, replace dome, replace cable,replace plastic cover and connector.... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE VolusonS6 VolusonS8 VolusonS10 RIC5-9W-RS

GE 3D/4D endocavity ultrasound probe RIC5-9W-RS replace dome and repair motor control problem Service scope: showing error, motor control problem, replace dome, replace cable,replace plastic cover... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE Repair flat panel DBM128 of GE Voluson S8. Repair flat panel DBM128 of GE Voluson S8.

Faulty Phenomenon Malfunction: during scanning with the use of the US transducer, an artifact in the form of uniform darkening of the entire visualization area is detected. Troubleshooting and... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE Repair GE Voluson E10. Repair GE Voluson E10.

Faulty Phenomenon Malfunction: when loading PO, a window appears with the message: Initialization and configuration of hardware failed. Starting simulation. Please restart system. After this... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE Repairing ultrasound GE Voluson E8 BT13. Repairing ultrasound GE Voluson E8 BT13.

Faulty Phenomenon Malfunction: Upon loading the device, the error "Mixed RSR configuration found" was fixed, due to which the system did not start. Troubleshooting and Solutions Malfunction: Upon... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE Repair GE Voluson E6 BT19. Repair GE Voluson E6 BT19.

Faulty Phenomenon Description of the problem: during the examination, flickering and interference appear on all sensors. The problem was progressive in nature, that is, with each time the... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE Repair GE Voluson E10 BT21. Repair GE Voluson E10 BT21.

Faulty Phenomenon Description of the problem: during the examination, all sensors display flickering and interference. The problem was progressive in nature, meaning that with each examination, the... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE Repair GE Voluson S8 BT16. Repair GE Voluson S8 BT16.

Faulty Phenomenon Description of the problem: when connecting both sensors of the RAB6-RS, an error appears in the Motor Control Unit. Troubleshooting and Solutions Description of the problem:... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE Repairing the ultrasound device GE ML6-15-D. Repairing the ultrasound device GE ML6-15-D.

Faulty Phenomenon Replacement of the acoustic lens (photo before replacement, inside the post - after... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE Repairing the ultrasound device GE RM6C. Repairing the ultrasound device GE RM6C.

Faulty Phenomenon Restoration of the sealing of the piston (problem: leakage of oil was detected under the piston). Troubleshooting and Solutions Restoration of the bellows seal (problem: an oil... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE Repairing GE Voluson E10 equipment. Repairing GE Voluson E10 equipment.

Faulty Phenomenon Malfunction: During the examination, artifacts appear in the form of bright spots, morgania, etc. With each examination, the artifacts increase. Solution: The malfunction was... voir plus

June 12  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE Repair equipment GE Logiq E9 R6. Repair equipment GE Logiq E9 R6.

Faulty Phenomenon Malfunction: when turning on, an error appears, associated with overheating of the device solution: the TO of the device was performed, and the MRX192 board was also repaired. ... voir plus

June 12  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE Repair ultrasound GE Logiq S8 R2. Repair ultrasound GE Logiq S8 R2.

Faulty Phenomenon Malfunction: Based on the results of the service testing, the board BF192 (5357234-20) is faulty. The malfunctioning channel has been identified as the cause of the device's... voir plus

June 12  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE Repair GE Logiq E9 R6 (XDClear 2.0). Repair GE Logiq E9 R6 (XDClear 2.0).

Faulty Phenomenon Malfunction: when turning on, a net image is displayed on the screen instead of the "dynamic circles" image, and non-existent sensors are also reflected. Replaced faulty... voir plus

June 30  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531