Over 10 California Auctions End Today - Bid Now
Over 550 Total Lots Up For Auction at Three Locations - VA 07/21, CA 07/22, KS 07/24

stats
DOTmed text ad

Probo Medical | We Buy, Repair, and Sell New and Used Ultrasound Equipment

We provide sales, service, rental, and repair for ultrasound systems, probes, and C-arms. We have the largest inventory in the world. Contact us about our special offers on certified refurbished equipment! Call: 317-759-9210 Email: sales@probomedical.com.

stats
stats
DOTmed text ad

North America's Ultimate Probe Repair Lab & Certified Refurbished OEM Probes in Stock

North America's trusted source for ultrasound probe repair and certified refurbished OEM probes. Free evaluations, 1-year warranty, fast turnaround for GE, Philips, Sonosite, Canon, Toshiba, and more. Call (224) 265-7640 / Sales@Lenard.Healthcare

DOTmed Certified stats
Mako meter by RTI Group
Mako meter by RTI Group
New Product Showcase
spacer
Par page

Annonces

Service For GE HEALTHCARE Repairing the ultrasound device GE RM6C. Repairing the ultrasound device GE RM6C.

Faulty Phenomenon Restoration of the sealing of the piston (problem: leakage of oil was detected under the piston). Troubleshooting and Solutions Restoration of the bellows seal (problem: an oil... voir plus

July 09  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE Repairing GE Voluson E10 equipment. Repairing GE Voluson E10 equipment.

Faulty Phenomenon Malfunction: During the examination, artifacts appear in the form of bright spots, morgania, etc. With each examination, the artifacts increase. Solution: The malfunction was... voir plus

June 12  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE Repair equipment GE Logiq E9 R6. Repair equipment GE Logiq E9 R6.

Faulty Phenomenon Malfunction: when turning on, an error appears, associated with overheating of the device solution: the TO of the device was performed, and the MRX192 board was also repaired. ... voir plus

June 12  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE Repair ultrasound GE Logiq S8 R2. Repair ultrasound GE Logiq S8 R2.

Faulty Phenomenon Malfunction: Based on the results of the service testing, the board BF192 (5357234-20) is faulty. The malfunctioning channel has been identified as the cause of the device's... voir plus

June 12  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE Repair GE Logiq E9 R6 (XDClear 2.0). Repair GE Logiq E9 R6 (XDClear 2.0).

Faulty Phenomenon Malfunction: when turning on, a net image is displayed on the screen instead of the "dynamic circles" image, and non-existent sensors are also reflected. Replaced faulty... voir plus

July 09  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE Repair GE Voluson E8 (BT12). Repair GE Voluson E8 (BT12).

Faulty Phenomenon A stripe appeared on the display of the RST board (PN: KTZ196358, KTZ280122). RST - impulse transmission board, 16 pieces are installed in the device (1 faulty). Sent the board... voir plus

July 09  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE Repair GE Logiq E10 (version R3). Repair GE Logiq E10 (version R3).

Faulty Phenomenon GE Logiq E10: A malfunction was detected in the TX board, an element that controls the switching on/off of high voltage for supply to the acoustic module has failed. The device is... voir plus

July 09  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE Repair device GE Philips Epiq 5. Repair device GE Philips Epiq 5.

Faulty Phenomenon Malfunction: error 607 indicates a malfunction in the data base solution: after restarting the PO device, it worked. Troubleshooting and Solutions Malfunction: error 607... voir plus

July 09  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE GE Voluson E8 BT21 device repair. GE Voluson E8 BT21 device repair.

Faulty Phenomenon Malfunction: During the examination, echo-imaging disappears and everything turns into white color. Solution: repair RFM323 plate. Troubleshooting and Solutions Malfunction:... voir plus

July 09  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE Repair device GE Voluson E10 B21. Repair device GE Voluson E10 B21.

Faulty Phenomenon Malfunction: during operation, a blue screen appears on the device. Sometimes the device does not turn on and the power button flashes yellow. Solution: repair the power supply... voir plus

July 09  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE GE Voluson E8 BT13.5 device overhaul. GE Voluson E8 BT13.5 device overhaul.

Faulty Phenomenon Malfunction: during operation of the device, a break occurred and an error Error on Power management (error in the power supply block) appeared. Solution: repair the RFM and RSX... voir plus

July 09  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE Repair GE Logiq E9. Repair GE Logiq E9.

Faulty Phenomenon Repair platform MRX192 (PN: 5393908) of Logiq E9 R6. Malfunction: the image quality has deteriorated, artifacts appeared on all transducers. Troubleshooting and Solutions Repair... voir plus

July 09  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE Repair GE Logiq E9. Repair GE Logiq E9.

Faulty Phenomenon Repair platform MRX192 (PN: 5393908) of Logiq E9 R6. Malfunction: the image quality has deteriorated, artifacts appeared on all transducers. Troubleshooting and Solutions Repair... voir plus

July 09  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE Repair GE Voluson S10 BT16. Repair GE Voluson S10 BT16.

Faulty Phenomenon Repair flat panel DBM128G Assy (PN: 5773602). Malfunction: during operation with the sensor on the display artifacts or interference of white color appear. Troubleshooting and... voir plus

July 09  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531

Service For GE HEALTHCARE Repair GE Logiq E9 R6. Repair GE Logiq E9 R6.

Faulty Phenomenon Repair block of power supply Main Power Supply (PN: 5205054). Malfunction: absence of 48V for the computer power supply block and therefore the device does not turn on. ... voir plus

July 09  
Doris Chou / Volka Medical Tech Co LTD
téléphone: +86 13076761531