Specifications for ALCON INFINITI 2.06 INTL Phacoemulsifier

Depth: 30 inches Height: 63 inches S/N: 0302203701X
Software Version: 2.06 Width: 23 inches Year of Manufacture: 2003 MPN: 210-000-503

Item Summary for ALCON INFINITI 2.06 INTL Phacoemulsifier

INTERNATIONAL 2.06 ver system Manufactured in 2003 this Alcon Infiniti Phacoemulsifier has been fully rebuilt and tested to factory specifications.



This system has 2.06 software version as well as Ozil handpiece compatibility. Included in this listing is the Alcon infiniti Vision System, foot pedal, foot pedal cable, operators manual, and dust cover. For an additional charge we also offer handpieces (Ozil, Ultrasonic, Neosonic, aqualase), remote control, and video overlay system.



This unit is intended for international sales only.

All domestic Alcon Infiniti vision systems purchased through our company are backed by a six month warranty!


---------------------------------------------


THE LISTED ERROR CODES ARE SHOWN ON THE INFINITI VISON SYSTEM DISPLAY PANEL WHEN THE SYSTEM DETECTS A PROBLEM. THE ERROR CODES ARE SEPARATED BETWEEN ADVISORIES, WARMNINGS, AND FAULTS.

Alcon Infinit Error Code 160: Reinsert FMS. Replace FMS if Problem Persists.

Alcon Infinit Error Code 161-164: Please Check Fittings and Reprime. Replace FMS if Problem Persists.

Alcon Infinit Error Code 165-167: Flow Obstruction. Please Check Handpiece Free Flow

Alcon Infinit Error Code 169: Irrigation Pressure is Low. Please Check Bottle and Fittings.

Alcon Infiniti Error Code 170: Reflux Terminated. Reflux Fluid Volume Depleted.

Alcon Infiniti Error Code 171: Excessive Pressure in Drain Bag. Replace FMS.

Alcon Infiniti Error Code 175-176: Infusion Pressure Sensor Calibration Error. Remove FMS. If Problem Persists, Contact Alcon Technical Services.

Alcon Infiniti Error Code 180: Invalid FMS ID. Replace FMS.

Alcon Infiniti Error Code 181: Excessive Ambient Light. Unable to Calibrate FMS ID Sensors.

Alcon Infiniti Error Code 182: Excessive Ambient Light. Unable to Read FMS ID.

Alcon Infiniti Error Code 183: Remove MultiPak FMS, See MultiPak Directions for Use

Alcon Infiniti Error Code 250: Tuning in Air

Alcon Infiniti Error Code 251: Insert Handpiece

Alcon Infiniti Error Code 252: Multiple Handpieces Detected. Remove a Handpiece.

Alcon Infiniti Error Code 254: Loose Tip

Alcon Infiniti Error Code 256-270: Replace Handpiece. If Problem Persists After Restarting System, Contact Alcon Technical Services.

Alcon Infiniti Error Code 271: Two Handpieces Detected. Remove a Handpiece.

Alcon Infiniti Error Code 272-274: Replace Handpiece. If Problem Persists After Restarting System, Contact Alcon Technical Services.

Alcon Infiniti Error Code 276: Ultrasound Error. Release Treadle and Retry. If Problem Persists After Restarting System, Contact Alcon Technical Services.

Alcon Infiniti Error Code 277: Handpiece Disconnected While Applying U/S Power. Release Treadle, then Insert and Tune Handpiece.

Alcon Infiniti Error Code 278: Replace Handpiece. If Problem Persists After Restarting System, Contact Alcon Technical Services.

Alcon Infiniti Error Code 279: Unknown Handpiece Detected.

Alcon Infiniti Error Code 280: Unsupported Handpiece Detected.

Alcon Infiniti Error Code 281: Cautery Compliance Error. If Problem Persists After Restarting System, Contact Alcon Technical Services.

Alcon Infiniti Error Code 282: Coagulator Error. If Problem Persists After Restarting System, Contact Alcon Technical Services.

Alcon Infiniti Error Code 350: Footswitch Failure Detected. Check Footswitch, Clean Under Rear Section of Treadle, and Remove Debris if Present. (Reference Maintenance Section of Operator’s Manual.) Ensure Treadle is Not Depressed, then Reset Footswitch. If Condition Persists, Contact Alcon Technical Services.

Alcon Infiniti Error Code 351: Footswitch Failure Detected. Check and Reset Footswitch. If Condition Persists, Contact Alcon Technical Services.

Alcon Infiniti Error Code 352: Footswitch Failure, Replace Footswitch.

Alcon Infiniti Error Code 353: Footswitch Failure Detected, Check and Reset Footswitch. If Condition Persists, Contact Alcon Technical Services.

Alcon Infiniti Error Code 450: Footswitch is Depressed, Release Footswitch Before Pressing Prime FMS, Fill, or Test Handpiece.

Alcon Infiniti Error Code 451: Can Not Recognize Footswitch. Please Check Footswitch Connection and Reset Footswitch. If Condition Persists, Contact Alcon Technical Services.

Alcon Infiniti Error Code 460: Please Install Footswitch.

Alcon Infiniti Error Code 461: Infiniti ® Backup Power Service Needed, Contact Alcon Technical Services.

Alcon Infiniti Error Code 463: Invalid Language(s) Found During Initialization. One or More Installed Languages May Not be Available.

Alcon Infiniti Error Code 464: The Language Specified by System Settings is Invalid.

Alcon Infiniti Error Code 465: The Tune Sequence was Interrupted by removal or the Handpiece.

dotmed


dotmed

Live Help!

We are offline at the moment

Leave a message

Need to ship this item?

Use DOTmed's Shipping Quote Service!
Get Started!

Publicité
Développez la notoriété de votre marque
Enchères + Ventes Privées
Obtenir le meilleur prix
Acheter des équipement / pièces
Trouver le meilleur prix
Infos du jour
Lire Les dernières nouvelles
Annuaire
Consulter tous les utilisateurs DOTmed
Éthique concernant DOTmed
Voir notre programme d'éthique
L'or partie le programme de fournisseur
Recevoir des demandes PH
Programme de marchand de service d'or
Recevoir des demandes
Fournisseurs de soins de santé
Voir tous les outils des HCP (abréviation pour les professionnels de la santé)
Les travaux/Formation
Trouver / combler un poste
Parts Hunter +EasyPay
Obtenir des devis de pièces
Certification Récentes
Voir les utilisateurs récemment certifiés
Evaluation Récentes
Voir les utilisateurs récemment certifiés
Central de location
Louer de l’équipement à moindre prix
Vendre des équipements / pièces
Obtenir le maximum d'argent
Service le forum de techniciens
Trouver de l'aide et des conseils
Simple demande de propositions
Obtenir des devis pour des appareils
Expo Virtuelle
Trouver des services d'appareils
L'Access et l'utilisation de cet emplacement est sujet aux modalités et aux conditions du notre de nos MENTIONS LEGALES & DONNEES PERSONELLES
Propriété de et classe des propriétaires DOTmedà .com, inc. Copyright ©2001-2017 DOTmed.com, Inc.
TOUS DROITS RÉSERVÉS