New WESTPRIME SYSTEMS OOM110 Oxygen Sensor Un Vendre - DOTmed Liste #786072:
This Item is no longer available.

Click here to see the 6 Equipment Listings matching 'WESTPRIME SYSTEMS OOM110 Oxygen Sensor' on DOTmed

Post a free Request For Proposal for a WESTPRIME SYSTEMS OOM110 Oxygen Sensor and get quotes from our Gold Service Dealers
WESTPRIME SYSTEMS OOM110 Oxygen Sensor for sale WESTPRIME SYSTEMS OOM110 Oxygen Sensor for sale WESTPRIME SYSTEMS OOM110 Oxygen Sensor for sale
WESTPRIME SYSTEMS OOM110 Oxygen Sensor for sale WESTPRIME SYSTEMS OOM110 Oxygen Sensor for sale WESTPRIME SYSTEMS OOM110 Oxygen Sensor for sale

A Vendre WESTPRIME SYSTEMS OOM110 Oxygen Sensor

  • Asking Price :$109.95 USD
  • Condition : New
  • Est. Shipping(US) : $9.95 USD
  • Qty. Available : 3
  • Date : April 03, 2020

Item Description

Seller assumes all responsibility for this listing.

Listing: #786072

  • Condition: New
  • Brand: WESTPRIME SYSTEMS
  • Type: Oxygen Sensor
  • Model: OOM110
  • MPN: B226-214
Oxygen Sensor OOM110

Made in Germany - ORIGINAL IN SEALED PACKAGING

For use with Datex Ohmeda: Aespire, Aestiva 3000, Airsys, Avance, Engstrom Modulus SE7900, Excel 210-7900, Modulus SE1700, S-5, Smart Vent.

Connector: Modular Jack 6P4C
Measurement Range: 0-100 % oxygen
Output in ambient air: 10 to 12mV
Electrical Interface: Modular Jack 6P4C
Accuracy and Repeatability: < 1 % vol. O2 when calibrated at 100 % Oxygen
Linearity error: < 3 % relative
Response time: < 12sec. to 90 % of final value
Zero Offset Voltage: < 200 µV in 100 % nitrogen applied after 5 min
Cross Interference: Meets EN ISO 21647 requirements
Influence of Humidity: - 0.03 % rel. per % RH at 25°C
Influence of Pressure: proportional to change in oxygen partial pressure
Influence of Mechanical Shock: < 1% relative after a fall from 1m
Operating Temperature: 0 to 50°C
Temperature Compensation: built-in NTC compensation
Effect of Temperature Compensation (steady state): relative error between 0 °C and +50 °C: 8 % relative error
Operating Humidity: 0-99% RH non-condensing
Long Term Output Drift: Storage Temperature: < 1 % vol oxygen per month typically < - 15 % relative over lifetime
Recommended Storage: +5 to +15 °C
Recommended Load: ≥ 10 kOhms
Warm-Up Time: < 30 minutes, after replacement of sensor
Nominal Sensor Lifetime: ≥ 1.000.000 % vol oxygen hours
Weight: approximately 50 grams
Part No. 01-00-0098

All specifications are applicable at standard conditions: 1013 hPa, 25°C dry ambient air

Advantages of Original German Made:
Meets EN ISO 21647
Designed and manufactured according to EN ISO 9001 and EN ISO 13485
Accurate and reliable response
Resistant to N2O
Excellent signal stability
High product quality