Over 150 New York Auctions End Tomorrow 04/19 - Bid Now
Over 1050 Total Lots Up For Auction at Two Locations - MA 04/30, NJ Cleansweep 05/02

Effect of gadolinium-based contrast agent on breast diffusion-tensor imaging

Press releases may be edited for formatting or style | August 07, 2020 Molecular Imaging Women's Health
Leesburg, VA, August 6, 2020—An “Original Research” article published in ARRS’ American Journal of Roentgenology (AJR) concluded that the accuracy of breast cancer diagnosis via diffusion-tensor imaging (DTI) was equivalent both before and after the administration of a gadolinium-based contrast agent (GBCA), despite a value change in DTI parameters.

“However,” wrote first author Anabel M. Scaranelo of Princess Margaret Cancer Centre’s breast imaging division in Toronto, “the limitations in standardization of contrast enhancement implies that unenhanced diffusion measurements should be preferred.”

In this pilot study, 26 women (age range 37–69 years) scheduled for a diagnostic breast MRI with BI-RADS categories 0, 4, 5, or 6 on conventional breast imaging were twice scanned using the same DTI sequence before and immediately after the breast dynamic contrast-enhanced MRI.
stats
DOTmed text ad

Your Centrifuge Specialty Store

Quality remanufactured Certified Centrifuges at Great prices! Fully warranted and backed by a company you can trust! Call or click for a free quote today! www.Centrifugestore.com 800-457-7576

stats
Using dedicated DTI software, quantitative image analysis yielded parametric DTI maps of each directional diffusion coefficient (DDC), mean diffusivity, and maximal anisotropy of the lesions and normal tissue. Using appropriate statistical tests, these color maps were evaluated and lesion DTI parameters were compared before and after GBCA administration.

Fifty-eight percent of the cohort had cancer (13 infiltrating ductal carcinoma, two ductal carcinoma in situ), and 42% had benign or normal results. All breast cancers were visually detected in the DDC λ1 maps before and after GBCA administration. Mean cancer size derived from λ1 maps before GBCA administration was 15.3 mm—not statistically significantly different from the size derived after GBCA administration.

After GBCA administration, the cancers exhibited statistically significantly lower DDCs, mean diffusivity, and b0 intensity (p < 0.05), and no change in maximal anisotropy compared with before GBCA administration, whereas these parameters in normal and benign lesions did not change significantly after GBCA administration. Mean AUC values before and after GBCA administration were not statistically significantly different for all parameters, aside from λ3.

Compared with before dynamic contrast enhancement, Scaranelo and colleagues’ results showed statistically significant reduction in the DDCs of breast cancers after dynamic contrast enhancement, “leading to equivalent or increased conspicuity of the cancer lesions in the visual assessment by the radiologist,” they noted.

Acknowledging the accuracy of breast cancer detection using unenhanced or contrast-enhanced DTI datasets was not significantly different, Scaranelo added that since DTI parameters are intrinsic tissue characteristics, the use of DTI before dynamic contrast enhancement can be fully standardized.

You Must Be Logged In To Post A Comment