Over 400 New Jersey Auctions End Tomorrow 04/25 - Bid Now
Over 1650 Total Lots Up For Auction at Four Locations - MA 04/30, NJ Cleansweep 05/02, TX 05/06, NJ 05/08

Volpara Solutions Awarded New FDA Clearance for Automated Breast Density Assessment Using ACR BI-RADS 5th Edition Categories

Press releases may be edited for formatting or style | November 24, 2015
WELLINGTON, New Zealand, November 9, 2015 –Volpara Solutions, the leading provider of automated breast density assessment and quantitative breast imaging tools, announced today that it has received a new 510(k) clearance from the U.S. Food & Drug Administration (FDA) for its VolparaDensity™ breast imaging software. Originally cleared for use by the FDA in 2010, Volpara Solutions technology is currently in use in 31 countries and more than 7-million women have had their breast density analysed using VolparaDensity.

The new clearance covers VolparaDensity version 3.1 which has been specifically designed to correlate to the new Fifth Edition of the Breast Imaging-Reporting and Data System (BI-RADS) Atlas recently issued by the American College of Radiology (ACR). The 5th Edition Atlas was updated to require "an overall assessment of the volume of attenuating tissues in the breast, to help indicate the relative possibility that a lesion could be obscured ... and that the sensitivity of examination thereby may be compromised by dense breast tissue." Development of Volpara's new software included a reader study which was used to optimize VolparaDensity performance to the BI-RADS 5th Edition.

Volpara will showcase VolparaDensity 3.1 software and other new advances to its suite of quantitative breast imaging tools at the upcoming Radiology Society of North America (RSNA) meeting, November 29-December 4, 2015 (South Hall booth #2377).

Because of its volumetric approach, VolparaDensity goes beyond measurement of dense tissue area, and actually measures the compressed thickness and volume of dense tissue to truly show when small regions of "focal density" present a masking risk. VolparaDensity results have also been clinically validated in independent studies to correlate to mammography sensitivity.[1]

Volpara has also developed a detailed discussion of the changes that have been made to VolparaDensity to reflect the new ACR BI-RADS Atlas 5th Edition including significant input from the Volpara customer base, study of the literature, reader study results, and research using in-house Volpara databases. Please contact us at info@volparasolutions.com to request a copy.

"This updated FDA clearance is significant as it supports the ability of Volpara to analyze breast density from both digital mammography and tomosynthesis images using the BI-RADS 4th Edition scale that radiologists are familiar with and also the new BI-RADS 5th Edition that a growing number of radiologists are migrating to," said Ralph Highnam, Ph.D., CEO, Volpara Solutions. "This is very exciting as it also comes right on the heels of an independent study recently published by researchers from the Netherlands which demonstrated that Volpara Density Grades showed substantial agreement with visual BI-RADS 5th Edition scores."

You Must Be Logged In To Post A Comment