Over 1850 Total Lots Up For Auction at Six Locations - MA 04/30, NJ Cleansweep 05/02, TX 05/03, TX 05/06, NJ 05/08, WA 05/09

spacer
Listing 2376132
Listing 2376132

For Sale CABLES AND SENSORS MAX-13 Oxygen Cell

  • Asking Price :$108.00 USD [convert]
  • Condition : New
  • Weight : 0.25 Lbs
  • Qty. Available : 10
  • Date : April 23, 2024
  • Listing # : 2376132
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #2376132

  • Condition: New
  • Brand: CABLES AND SENSORS
  • Type: Other
  • Model: MAX-13
  • MPN: G0-030
  • Depth: 4 inches
  • Height: 6 inches
  • Width: 6 inches
  • Warranty: 6 Months

The Maxtec MAX-13 Oxygen Cell is an FiO2 (Fraction of Inspired Oxygen) Sensor that is primarily used with ventilator machines. Check below for specific compatibility information.

*Note: Can only be shipped within the U.S.

Maxtec MAX-13 Oxygen Cell Specifications:
  • #G0-030 (Generic Equivalent):
    • Response Time: Less than 12 seconds.
    • Connector Type: 3.5 mm Mono Jack.
    • Compatible With:
      • BMD (Bio-Med Devices): M-10, M-2.
      • Bird: 6400, 8400, VIP, Sentry.
      • Covidien-Puritan Bennett: 7820, PB 850.
      • Datex-Ohmeda: 7200, Engstrom Elvira, Engstrom Erica.
      • MSA: MiniOx III.
      • Respironics: Esprit Lifecare.
    • OEM Part #:
      • BMD (Bio-Med Devices): 10006.
      • Biotest: C102-1.
      • Bird: 66030.
      • Ceramatec: CAG-13.
      • Covidien-Puritan Bennett: 4-020933-00.
      • Dameca: 42035-46.
      • Datex-Ohmeda: 6051-0000-217.
      • Draeger-Air Shields: 6735142.
      • Envitec: OOM-103-1, OOM-202-1.
      • Hamilton Medical: HM-11.
      • Henleys: 5567.
      • Hudson RCI: V-11.
      • ITG: M-03.
      • Integral Process: 65005.
      • Invivo: 9445.
      • Kontron: ABT 5100.
      • Lifecare: PLV-100, 37-079.
      • MSA: 406931.
      • Mercury Medical: 10-103-05.
      • Nuova: E-17/J.
      • Oxitron: 3310.
      • Pacifitech: PT--11A.
      • Sensidyne: SV-11A.
      • SensorTech: ST-11.
      • Smiths Medical-BCI: R-17.
      • VTI: 100580.
      • Ventrex: V-14A.
      • Viamed: R-41V.
  • #R115P10 (Original):
    • Output: 9 to 17 mV.
    • Response Time: ‰¤ 13 seconds.
    • Linearity: Less than 3% error.
    • Replacement For:
      • Analytical Industries: PSR-11-917-J.
      • City Technology: MOX-2.
      • Covidien: 4-020933-00, 7820 Monitor, 7200 Vent.
      • Datascope: Anestar S.
      • EnviteC: OOM-102-1.
      • Hill-Rom: 6735142.
      • Invivo: 9445 Sensor.
      • MSA: 406931, MiniOX 3000, MiniOX II, MiniOX III.
      • Mercury Medical: 10-103-05.
      • Pacifitech: PT-11A.
      • Philips (Respironics): Criterion Vent, Espirit Vent Lifecare (#PLV-102), 37-079 Sensor.
      • Precision Medical: PM5900, 504877.
      • Teledyne: R17MED #C-43690.
      • Teleflex (Hudson): 5567, V-11.
      • VTI: 100580.
      • Viasys: 66030 Sensor, 6400 Vent, 8400 Vent, VIP Vent.
Maxtec MAX-13 Oxygen Cell Configurations:
  • #G0-030: Generic Equivalent (Manufactured by Cables and Sensors).
    • Warranty: 6 Months - Free of Manufacturing Defects.
  • #R115P10: Original (Manufactured by Maxtec).
    • Warranty: 14 Months.
Maxtec MAX-13 Oxygen Cell