For Sale BECKMAN COULTER OLYMPUS AU 680 Chemistry Analyzer

  • Condition : Used - Excellent
  • Qty. Available : 1
  • In Stock : Yes
  • Date : March 17, 2024
  • Listing # : 2962508
Advertisement

Item Description

Seller assumes all responsibility for this listing..

Listing: #2962508

  • Condition: Used - Excellent
  • Brand: BECKMAN COULTER OLYMPUS
  • Type: Chemistry Analyzer
  • Model: AU 680
  • MPN: IDE-AU680
We have a Beckman Coulter / Olympus AU 680 Chemistry Analyzer For Sale or Lease

The AU680 clinical chemistry analyzer gives mid- to high-volume laboratories the flexibility to improve efficiencies and economics their way. Operate the AU680 as a standalone system or connect it to laboratory automation and IT solutions. With throughput of up to 800 photometric tests per hour (up to 1,200 with ISEs) and 63 onboard parameters, the AU680 delivers field-proven reliability and efficiency to laboratories around the world.

FEATURES:

- The intuitive graphical user interface includes:
- Sample tracking
- Patient statistics
- User-customized menu
- Color alerts to highlight system operating conditions
- AU-proven reliability enables greater uptime with quick and easy parts replacement
- No tools required
- No more than three steps, no longer than 60 seconds, for parts such as sample and reagent probes, mixers and syringes
- Online help videos guide the operator on proper technique when performing maintenance procedures and parts replacement, which enables greater system uptime 
- Integration of pre-analytical automation and immunoassay is attainable with AU680 Direct Track Sampling to Power Processor and connectivity to UniCel DxI 600/800 systems
- Command Central integrated with REMISOL Advance* enables remote monitoring of and access to instruments and automation consoles from a single workstation, optimizing laboratory management and improving decision-making
- Cooled STAT compartment provides one-button STAT interrupt and advanced auto QC and calibration capabilities
- High-precision microsampling provides accurate and precise results
- Priority sample repeat/reflex reduces turnaround time for critical patients  
- Long-lasting ISEs minimize downtime and reduce operating costs
- Large 150-sample rack loader provides for optimal sample processing during peak workload periods
- Whole blood sampling capability is used for HbA1c testing



SPECIFICATIONS:

Analytical System: Fully automated, random-access clinical chemistry system with STAT capability
Analytical Principles: Spectrophotometry and potentiometry
Analytical Types: Endpoint, rate, fixed point and indirect ISE
Analytical Methods: Colorimetry, turbidimetry, latex agglutination, homogeneous EIA, indirect ISE
Simultaneously Processed Analytes: 60 photometric tests + 3 ISE
Throughput: 800 photometric tests/hour; up to 1,200 with ISE
Sample Types: Serum, plasma, urine, whole blood (HbA1c) and other fluids
Sample Feeder: Racks with 10 samples each (barcodes on primary tubes and on racks); capacity of 150 samples; continuous loading
Sample Tubes: In primary and secondary tubes; diameter between 11.5 and 16.5 mm; height between 55 and 102 mm
STAT Samples: Up to 22 positions for STAT samples, barcoded primary tubes
Sample Volume: 1–25 μL in 0.1 μL increments (1–25 μL for repeats)
Reagent Supply: 60 positions for R1, 48 positions for R2; refrigerated: 4–12°C; handling of 3-shot reagents
Reagent Volume: R1: 15–250 μL; R2: 15–250 μL; in 1 μL increments
Total Reaction Volume: 120–425 μL
Reaction Cuvette: Quartz cuvettes
Reaction Time: Up to 8 minutes, 40 seconds
Reaction Temperature: 37°C
Mixing Method: With rotating paddles after dispensing sample and reagent
Photometry System: Direct assay through the reaction cuvette (0–3.0 OD) mono and bichromatic measurements possible
Wavelength: 13 different wavelengths between 340–800 nm
Cuvette Cleaning: Comprehensive cleaning with detergents
Calibration: Autocalibration, cooled calibrator positions; master calibration established by two-dimensional barcode on the reagent bottle (>3-point calibration)
Quality Control: Auto QC, cooled QC positions
Test Requisition: Individual and profile test requisition via online, mouse, function keys or touch screen
Safety: Clot detection and crash prevention for sample and reagent dispenser
Online: Full uni- and bi-directional communication possible
Software: Windows 7®
Data Storage: Sample number: 100,000 samples. Reaction data: 200,000 tests.
Dimensions (WxHxD): ANL 1,950x1,280x1,000
Power Supply: 200 V; 208 V; 220 V; 230 V; 240 V; 50 Hz; 60 Hz/3.8 KVA